Concrete Strength Test Report
|
| M.I.I.,
INC Job#: |
03-100/L |
| Date: |
1/17/2006 |
| Project: |
Slater Concrete Products |
| Client: |
Lone Star Industries |
| Pour
Location: |
Block/Brick Test Mix |
| Concrete
Source: |
Slater Concrete Products |
Mix Properties
|
| Sacks of
Cement: |
Block/Brick Mix |
| Type of
Cement: |
Lone Star I-A |
Physical Test Properties
|
| Required
Strength (PSI): |
3000 PSI @ 28 Days |
| Field
Cured (Days): |
3 |
| Cylinders
Cast By: |
Client |
Concrete Compressive Strength Results
|
| Sample
# |
Date
Cast |
Date Tested |
Age Days |
Total Load |
Strength (psi) |
| #7140 |
1/17/2006 |
1/24/2006 |
7 |
34,500 |
2790 |
| #7141 |
1/17/2006 |
1/24/2006 |
7 |
35,000 |
2825 |
| #7142 |
1/17/2006 |
2/14/2006 |
28 |
39,000 |
3181 |
| #7143 |
1/17/2006 |
2/14/2006 |
28 |
39,500 |
3165 |
Facing Information
|
| 1 |
Face on
block - 6000 P.S.I. |
| 2 |
Face
Control - 1 block in each 100 tested for bonding. |
| 3 |
Face
Bonding - Past 20 years, have not had any loss of bonded
face, including weather testing. |
|
Remarks:
Per Batch Wgts. SAND 1728/PEA
GRAVEL 432/CEMENT 248